Sterile Cord Blood Collection Unit (Msc128d) (anticoagulant citrate phosphate dextrose solution) - Dosing, PA Forms & Info (2026)
logo
Sign In
Farxiga vs. GlyxambiBerinert vs. CinryzeEmgality vs. QuliptaFarxiga vs. InvokanaFirazyr vs. SajazirGlyxambi vs. InvokanaInvokamet vs. SynjardyOpzelura vs. DupixentOrencia vs. RinvoqQulipta vs. VyeptiStelara vs. TremfyaSynjardy vs. VictozaTaltz vs. BimzelxVyepti vs. Nurtec ODTView all Comparisons
ADHD drugsAnxiety drugsAsthma drugsAtopic dermatitis drugsDepression drugsHeart failure drugsHypertension drugsLymphoma drugsOsteoarthritis drugsRheumatoid arthritis drugsRosacea drugsSchizophrenia drugsType 2 Diabetes drugsView all Indications
Bayer drugsAbbVie drugsAstraZeneca drugsEli Lilly and Company drugsGenetech drugsGlaxoSmithKline (GSK) drugsNovartis drugsPfizer drugsTakeda Pharmaceuticals drugsTeva Pharmaceuticals drugsAmgen drugsView all Manufacturers
Beta-Adrenergic BlockerAngiotensin Converting Enzyme InhibitorAngiotensin 2 Receptor BlockerCalcium Channel BlockerDiureticsHMG-CoA Reductase InhibitorProton Pump InhibitorSelective Serotonin Reuptake InhibitorNorepinephrine Reuptake InhibitorBenzodiazepinesOpioid AgonistsNonsteroidal Anti-inflammatory DrugsAntiepileptic AgentsAntipsychoticsAntihistaminesView all Classes
Wegovy®Ozempic®Mounjaro®Zepbound®Jardiance®Farxiga®Dupixent®Trulicity®Lyrica®Lipitor®Effexor®Concerta®Depakote®Trintellix®Rexulti®Rinvoq®Verzenio®Taltz®
PrescriberPoint
HIPAA Logo
HIPAA COMPLIANT
SOC 2 Logo
Soc 2 Type II
PrescriberPoint
HIPAA Logo
HIPAA COMPLIANT
SOC 2 Logo
Soc 2 Type II
For ProvidersRequest DemoJoin Research Panel
Prescribing toolsPrescribing InfoCoverageSavingsPatient ResourcesA-Z IndicationsCompare Drugs
CompanyAboutCareersContact UsSecurity
Get the latest insights in your inbox
  • Terms and Conditions
  • Privacy Policy
  • © 2026 PrescriberPoint. All Rights Reserved.
    1. Home
    2. Sterile Cord Blood Collection Unit (Msc128d)- Anticoagulant Citrate Phosphate Dextrose Solution injection, Solution

    Get your patient on Sterile Cord Blood Collection Unit (msc128d)- Anticoagulant Citrate Phosphate Dextrose Solution injection, Solution (Anticoagulant Citrate Phosphate Dextrose Solution)

    Medication interactionsSee all drug-to-drug interactions for this medication.
    card icon
    Prescribing informationPubMed™ news

    Sterile Cord Blood Collection Unit (Msc128d)- Anticoagulant Citrate Phosphate Dextrose Solution injection, Solution prescribing information

    • Indications & usage
    • Description
    • How supplied/storage & handling
    • Instructions for use
    • Data source
    • Indications & usage
    • Description
    • How supplied/storage & handling
    • Instructions for use
    • Data source
    Prescribing Information
    Indications & Usage

    INDICATIONS AND USAGE

    MSC128D - For collection of up to 200 mL of umbilical cord blood. Use aseptic technique.

    Description

    MACO BIOTECH Collection - Sterile Cord Blood Collection Unit (MSC128D)

    The MSC128D Sterile Cord Blood Collection Unit consists of 300 mL collection bag containing 21 mL of Anticoagulant Citrate Phosphate Dextrose Solution USP (CPD), a 40 mL rinsing bag containing 8 mL of CPD and two 12 gauge needles with a protective shield (SECUVAM) for the used needle.

    Sterile, non-pyrogenic fluid path. Sterilized by steam.

    Rx only .

    This product is not made with natural rubber latex.

    How Supplied/Storage & Handling

    HOW SUPPLIED

    MSC128D Sterile Cord Blood Collection Unit contains:

    • 300 mL collection bag containing 21 mL CPD
    • 40 mL rinsing bag containing 8 mL CPD
    • 2-12 gauge needles with a protective shield (SECUVAM) for used needle
    • Graduation label as visual aid to approximate the volume.
    Instructions for Use

    INSTRUCTIONS FOR USE
    Carefully Read All the Instructions Before Use

    Representative Product Drawing

    Referenced Image

    I.       PREPARATION

    • Before use, verify the integrity of the collection unit (overwrap, outlet ports, tubing...).
    • Only contents inside the inner wrap are sterile and acceptable for use in a sterile field if pouch is unopened and undamaged.

    II.    COLLECTION PROCEDURE

    • Close all clamps 3A, 3B and 3C (clamp 9 should remain open).
    • After clamping and sectioning of the umbilical cord, place the collection bag on a mixer and perform a venipuncture at lower end of the umbilical cord with first needle 1A.

    Note :  Umbilical venipunctures can be done before or after the expulsion of the placenta according to your local procedures.

    3.  Open clamps 3A and 3C.

    4.  Stimulate cord blood flow by massaging the cord from the top downward to increase volume of collection.

    5.  When collection is completed, close clamps 3A and 3C.

    6.  Remove needle 1A and slide down SECUVAM 2A (needle protector) over needle 1A.

    7.  If necessary, perform a second umbilical venipuncture on the upper part of the umbilical cord (near the mother)

    [See Warnings]:

    a.  Open clamps 3B and 3C.

    b.  Perform venipuncture on the umbilical cord using other needle 1B.

    c.  When collection is completed, close clamps 3B and 3C.

    d.  Remove needle 1B and slide down SECUVAM 2B (needle protector) over needle 1B.


    III.    RINSING OF COLLECTION LINE

    • Open clamp 3C.
    • Snap the break-away cannula on top of rinsing bag 6.
    • Roll up bag 6 on itself to empty 8 mL of anticoagulant (CPD) in the tubing to push the cord blood remaining in the tubing into the collection bag.  Do not strip the tubing.
    • Close clamp 3C.
    • Proceed to section V END OF COLLECTION if collection volume is less than 150 mL.  For collection volumes greater than 150 mL, proceed to section IV ADDITION OF ANTICOAGULANT INTO THE COLLECTION BAG.

    IV.    ADDITION OF ANTICOAGULANT INTO THE COLLECTION BAG

    Use this step only for collection volumes greater than 150 mL.

    • Seal the tubing above Y junction 5.
    • Move clamp 3C near to Y junction 5.
    • Using a blood stripper, strip the tubing from Y junction 5 towards collection bag 8 expelling the anticoagulant in the tubing into collection bag 8.
    • Repeat this operation 3 times.
    • Mix collection bag 8.
    • Close clamp 3C.
    • Proceed to section V END OF COLLECTION.

    V.   END OF COLLECTION

    • Close clamp 9 to secure the collection.
    • Seal the tubing between clamp 9 and collection bag 8.
    • Fill in collection volume and CPD volume on the collection bag label.  The amount of CPD is as follows:

    a.  21 mL - if no additional CPD is added.

    b.  29 mL - if additional 8 mL CPD from rinsing bag is added to the collection bag as directed in section IV.

    4.  For optimal cord blood quality, maintain the cord blood at an ambient temperature (18-26°C / 64.4-78.8°F) or cold temperature (4-12°C / 39.2-53.6°F).

    VI.    CONTACT INFORMATION

    Manufactured for United States of America (U.S.A.) and Canada by Maco Productions Polonia, Sp. z o.o.

    ul. Szwajcarska 22, 54-405 Wroclaw, POLAND

    +48 71 37 60 110

    For consumer information contact:

    • For the U.S.A.: Distributed by Uneklo USA, Inc. dba Macopharma USA

    3075 Breckinridge Boulevard, Suite 405, Duluth, GA 30096, USA

    (770) 270-6867

    • For Canada: Distributed by Macopharma Canada

    1200 McGill College, Suite 1715, Montreal (Quebec) H3B 4G7

    (514) 866-2222

    VII.   REFERENCES

    • Pope, B. Mitsakos, K., Bilgin, A., Hokin, B. and Grant, R.:  Predicting overall viability of cord blood harvests.  Transfusion 2012:52:1079-1085
    • Salge-Bartels U. Huber. M, Kleiner K, Volkers P, Seitz R, Heiden M:  Evaluation of Quality Parameters for Cord Blood Donations. Transfus Med Hemother 2009; 36:317-324
    • Prof. Dr. Kogler, Jose Carreras CBB, medical center, University of Duesseldorf:  General information on the institution and the production facility of the Jose Carreras Cord Blood Bank. 2014
    Data SourceWe receive information directly from the FDA and PrescriberPoint is updated as frequently as changes are made available
    Report Adverse Event
    Interactions Banner
    Check medication interactionsReview interactions as part of your prescribing workflow

    Sterile Cord Blood Collection Unit (Msc128d)- Anticoagulant Citrate Phosphate Dextrose Solution injection, Solution PubMed™ news

      Show the latest PubMed™ articles for Sterile Cord Blood Collection Unit (Msc128d)- Anticoagulant Citrate Phosphate Dextrose Solution injection, Solution