Choletec (mebrofenin) - Dosing, PA Forms & Info (2026)
logo
Sign In
Farxiga vs. GlyxambiBerinert vs. CinryzeEmgality vs. QuliptaFarxiga vs. InvokanaFirazyr vs. SajazirGlyxambi vs. InvokanaInvokamet vs. SynjardyOpzelura vs. DupixentOrencia vs. RinvoqQulipta vs. VyeptiStelara vs. TremfyaSynjardy vs. VictozaTaltz vs. BimzelxVyepti vs. Nurtec ODTView all Comparisons
ADHD drugsAnxiety drugsAsthma drugsAtopic dermatitis drugsDepression drugsHeart failure drugsHypertension drugsLymphoma drugsOsteoarthritis drugsRheumatoid arthritis drugsRosacea drugsSchizophrenia drugsType 2 Diabetes drugsView all Indications
Bayer drugsAbbVie drugsAstraZeneca drugsEli Lilly and Company drugsGenetech drugsGlaxoSmithKline (GSK) drugsNovartis drugsPfizer drugsTakeda Pharmaceuticals drugsTeva Pharmaceuticals drugsAmgen drugsView all Manufacturers
Beta-Adrenergic BlockerAngiotensin Converting Enzyme InhibitorAngiotensin 2 Receptor BlockerCalcium Channel BlockerDiureticsHMG-CoA Reductase InhibitorProton Pump InhibitorSelective Serotonin Reuptake InhibitorNorepinephrine Reuptake InhibitorBenzodiazepinesOpioid AgonistsNonsteroidal Anti-inflammatory DrugsAntiepileptic AgentsAntipsychoticsAntihistaminesView all Classes
Wegovy®Ozempic®Mounjaro®Zepbound®Jardiance®Farxiga®Dupixent®Trulicity®Lyrica®Lipitor®Effexor®Concerta®Depakote®Trintellix®Rexulti®Rinvoq®Verzenio®Taltz®
PrescriberPoint
HIPAA Logo
HIPAA COMPLIANT
SOC 2 Logo
Soc 2 Type II
PrescriberPoint
HIPAA Logo
HIPAA COMPLIANT
SOC 2 Logo
Soc 2 Type II
For ProvidersRequest DemoJoin Research Panel
Prescribing toolsPrescribing InfoCoverageSavingsPatient ResourcesA-Z IndicationsCompare Drugs
CompanyAboutCareersContact UsSecurity
Get the latest insights in your inbox
  • Terms and Conditions
  • Privacy Policy
  • © 2026 PrescriberPoint. All Rights Reserved.
    1. Home
    2. Choletec - Mebrofenin injection, Powder, Lyophilized, For Solution

    Get your patient on Choletec - Mebrofenin injection, Powder, Lyophilized, For Solution (Mebrofenin)

    Prescribing informationPubMed™ news

    Choletec - Mebrofenin injection, Powder, Lyophilized, For Solution prescribing information

    • Indications & usage
    • Dosage & administration
    • Contraindications
    • Adverse reactions
    • Description
    • Pharmacology
    • How supplied/storage & handling
    • Data source
    • Indications & usage
    • Dosage & administration
    • Contraindications
    • Adverse reactions
    • Description
    • Pharmacology
    • How supplied/storage & handling
    • Data source
    Prescribing Information
    Indications & Usage

    INDICATIONS AND USAGE

    Technetium Tc 99m Mebrofenin is indicated as a hepatobiliary imaging agent.

    Dosage & Administration

    DOSAGE AND ADMINISTRATION

    The suggested intravenous dose range of Technetium Tc 99m Mebrofenin in the average patient (70 kg) is:

    Nonjaundiced patient: 74-185 MBq (2-5 mCi)
    Patient with serum
    bilirubin level greater
    than 1.5 mg/dL:
    111-370 MBq (3-10 mCi)

    The patient dose should be measured by a suitable radioactivity calibration system immediately prior to administration.

    The patient should be in a fasting state, 4 hours is preferable. False positives (non-visualization) may result if the gallbladder has been emptied by ingestion of food.

    An interval of at least 24 hours should be allowed before repeat examination.

    Parenteral drug products should be inspected visually for particulate matter and discoloration prior to administration whenever solution and container permit.

    Contraindications

    CONTRAINDICATIONS

    Hypersensitivity to this compound.

    Adverse Reactions

    ADVERSE REACTIONS

    Urticaria and rash have been rarely reported with the use of Technetium Tc 99m Mebrofenin since market introduction. Rare cases of chills and nausea have been reported with related compounds. Infrequently, death has been reported in association with the use of this class of agents.

    Description

    DESCRIPTION

    Each reaction vial contains a nonradioactive, sterile, nonpyrogenic mixture of 45 mg mebrofenin, 0.54 mg (minimum) stannous fluoride dihydrate, SnF 2 •2H 2 O and 1.03 mg total tin, maximum (as stannous fluoride dihydrate, SnF 2 •2H 2 O), not more than 5.2 mg methylparaben, and 0.58 mg propylparaben. The pH is adjusted with sodium hydroxide or hydrochloric acid prior to lyophilization. The contents of the vial are lyophilized and sealed under nitrogen at the time of manufacture.

    The pH of the reconstituted product is 4.2 to 5.7.

    The structure of mebrofenin (2,2’-[[2-[(3-Bromo-2,4,6-trimethylphenyl)-amino]-2-oxoethyl]imino] bisacetic acid) is shown below:

    Referenced Image

    When sterile, pyrogen-free sodium pertechnetate Tc 99m injection is added to the vial, the diagnostic agent Technetium Tc 99m Mebrofenin is formed for administration by intravenous injection.

    Pharmacology

    CLINICAL PHARMACOLOGY

    Mebrofenin is an iminodiacetic acid (HIDA) derivative with no known pharmacologic action at the recommended doses.

    Following intravenous administration in normal subjects, Technetium Tc 99m Mebrofenin was rapidly cleared from the circulation. The mean percent injected dose remaining in the blood at 10 minutes was 17%. The injected activity was cleared through the hepatobiliary system with visualization of the liver by 5 minutes and maximum liver uptake occurring at 11 minutes post-injection. Hepatic duct and gallbladder visualization occurred by 10 to 15 minutes and intestinal activity was visualized by 30 to 60 minutes in subjects with normal hepatobiliary function. The mean percent injected dose excreted in the urine during the first 3 hours was 1% (0.4 to 2.0%).

    Elevated serum bilirubin levels increase renal excretion of Tc 99m HIDA agents. In two studies in which Tc 99m Mebrofenin was administered to patients having mean elevated serum bilirubin levels of 9.8 mg/dL (1.7 to 46.3 mg/dL), the mean percent injected dose excreted in the urine during the first 3 hours was 3% (0.2 to 11.5%). The mean percent injected dose excreted in the urine during 3-24 hours was 14.9% (0.4 to 34.8%).

    In jaundiced patients, the percent injected dose remaining in the blood at 10 minutes may be twice as high or more than the level in normals. Hepatobiliary transit may be delayed and visualization times increased. As a consequence, the quality of the images obtained frequently diminishes.

    How Supplied/Storage & Handling

    HOW SUPPLIED

    Choletec (Kit for the Preparation of Technetium Tc 99m Mebrofenin) is supplied in kits of 10 reaction vials. Each vial contains a sterile, nonpyrogenic lyophilized mixture of 45 mg mebrofenin, 0.54 mg (minimum) stannous fluoride dihydrate, SnF 2 •2H 2 O and 1.03 mg total tin, maximum (as stannous fluoride dihydrate, SnF 2 •2H 2 O), not more than 5.2 mg methylparaben, and 0.58 mg propylparaben. The pH has been adjusted with hydrochloric acid or sodium hydroxide prior to lyophilization. The lyophilized vial contents are sealed under nitrogen at the time of manufacture. The pH of the reconstituted product is 4.2 to 5.7.

    Kit Contents

    10 sterile multidose reaction vials.
    20 pressure-sensitive labels for Technetium Tc 99m Mebrofenin.
    1 package insert.

    Preparation

    Preparation of Technetium Tc 99m Mebrofenin is done by the following aseptic procedure:

    1. Waterproof gloves should be worn during the preparation procedure.
    2. Place reaction vial in an appropriate lead shield.
    3. Swab the rubber closure of the reaction vial with a germicide.
    4. Inject 1 to 5 mL sterile additive free sodium pertechnetate Tc 99m injection containing up to 3700 MBq (100 mCi) Tc 99m into the reaction vial. Be sure to maintain a nitrogen atmosphere in the vial by not introducing air during reconstitution.
      NOTE: If sodium pertechnetate Tc 99m injection must be diluted for use with Choletec (Kit for the preparation of Technetium Tc 99m Mebrofenin), only preservative free Sodium Chloride Injection USP should be used.
    5. Secure the lead shield cover. Swirl the vial gently to mix contents and let stand for 15 minutes.
    6. Record the date and time of preparation on pressure-sensitive label.
    7. Affix pressure-sensitive label to shield.
    8. Examine vial contents. If the solution is not clear and free of particulate matter and discoloration on visual inspection, it should not be used.
    9. Measure the radioactivity by a suitable calibration system and record on the shield label prior to patient administration.
    10. Withdraw material with a sterile lead shielded syringe for use within 18 hours of preparation.

    Storage

    Store the kit as supplied at 20-25°C (68-77°F) [See USP] prior to and following reconstitution. Use within 18 hours of reconstitution.

    The U.S. Nuclear Regulatory Commission has approved this reagent kit for distribution to persons licensed to use byproduct material identified in §35.200 of 10 CFR Part 35, to persons who hold an equivalent license issued by an Agreement State, and, outside the United States, to persons authorized by the appropriate authority.

    Data SourceWe receive information directly from the FDA and PrescriberPoint is updated as frequently as changes are made available
    Report Adverse Event

    Choletec - Mebrofenin injection, Powder, Lyophilized, For Solution PubMed™ news

      Show the latest PubMed™ articles for Choletec - Mebrofenin injection, Powder, Lyophilized, For Solution